Keeping on top of Fire Risk Assessments can feel like another recurring chore for busy landlords and building managers. Yet when you weigh up the safety of your tenants, staff, and visitors alongside strict UK fire legislation, regular reviews are one of the most practical safeguards you can put in place.

Fire Risk Assessment inspection checklist and building safety review

Knowing how often to schedule a review comes down to how your building is used and what changes over time. Alterations to floor layouts, new occupancy levels, and updated equipment all affect how a fire could start or spread, so timing your reviews properly keeps your premises both safe and legally compliant.

How Often Should You Review a Fire Risk Assessment?

UK fire safety law does not set a single rigid calendar expiry date for a Fire Risk Assessment (FRA). Instead, GOV.UK workplace fire safety guidance requires the Responsible Person to keep the assessment under regular review and update it whenever there is reason to suspect it is no longer valid or following significant changes.

As a practical benchmark across London HMOs, blocks of flats, and commercial premises, most insurers and local authorities expect a documented review every 12 months, alongside an immediate reassessment after structural alterations, changes of use, or a fire incident. At Landlord Certificate London, Fire Risk Assessments start from £74, with communal-area assessments up to 3 floors at £149.99 and commercial assessments up to 3 floors at £249.99.

Review TriggerRecommended ActionWhy It Matters
Annual Scheduled ReviewReview existing FRA every 12 monthsConfirms escape routes, alarms, and emergency plans remain current even if nothing major changed.
Building or Layout WorksCommission a fresh FRA immediatelyNew partitions, extensions, or altered escape corridors can compromise compartmentation and travel distances.
Occupancy or Tenant ChangesUpdate risk profile before occupationHigher headcounts, HMO conversions, or vulnerable residents change evacuation requirements.
Near-Miss or Fire IncidentFull reassessment and remedial checkIdentifies root causes and verifies that existing controls performed as intended.

Why Fire Door Inspections Matter

Accredited assessor checking fire door seals, hinges, and self-closing mechanism

A Fire Risk Assessment relies heavily on passive fire protection, and fire doors are your building’s primary barrier against smoke and flames. Under the Fire Safety (England) Regulations 2022 fire door guidance, Responsible Persons for multi-occupied residential buildings over 11 metres must carry out quarterly checks on communal fire doors and annual checks on flat entrance doors.

Self-Closing Mechanism

Doors must shut firmly into the frame from any opening angle without sticking, dragging, or being wedged open.

Intumescent & Smoke Seals

Continuous, undamaged strips and brushes around the frame are essential to block toxic smoke and heat spread.

Gaps, Hinges & Signage

Check perimeter gaps (typically 2mm to 4mm), CE-marked hinges, and clear “Fire Door Keep Shut” signs.

Certified Door Surveys

Arrange a dedicated fire door inspection (from £120) whenever doors are replaced or show wear.

Preventing Fire Alarm False Alarms

Repeated false alarms do more than frustrate residents and staff: they cause alarm fatigue, leading people to ignore genuine warnings, and can result in Fire and Rescue Services withholding automatic attendance. Keeping detectors clean of dust, steam, and insect debris through routine servicing prevents most nuisance activations.

Equally important is matching the right detector head to each room (for example, heat detectors in kitchens rather than optical smoke sensors) and training staff or tenants on proper call-point use. Scheduling regular BS 5839 alarm testing alongside your FRA keeps both your detection system and your logbook up to standard.

Practical Arson Risk Reduction Strategies

Deliberate fire-setting remains a major hazard for commercial premises, vacant units, and residential bin stores. Following London Fire Brigade arson prevention advice, simple physical controls such as keeping wheelie bins chained well away from external walls and windows dramatically lower external fire risks.

Good perimeter lighting, working CCTV, secure access control on staff-only or communal doors, and locking away flammable stocks or waste pallets at the end of each working day further reduce opportunity. Training staff to spot suspicious behaviour and report damaged fencing or letterboxes adds an extra layer of protection.

Hassan Sharif, Business Development Manager and Compliance Specialist

“Across converted London properties and high-street shops, the two items that trip up otherwise compliant owners most often are propped-open fire doors and overflowing rubbish bags stacked right against ground-floor windows. Fixing those housekeeping habits before your annual FRA review usually eliminates the highest-priority hazards on the spot.”

Hassan Sharif, Business Development Manager & Compliance Specialist (View Profile)

Fire Extinguisher Selection and Maintenance

Portable fire extinguishers positioned along an escape route

Portable firefighting equipment only works if the right unit is mounted in the right place and serviced on schedule. Under UK British Standards (BS EN 3 and BS 5306-8) outlined in the London Fire Brigade portable firefighting equipment guidance, extinguishers are matched to specific UK fire classes: Class A (wood, paper, textiles), Class B (flammable liquids), Class C (flammable gases), Class D (metals), and Class F (cooking oils and fats).

Extinguishers should sit on escape routes and near exit doors where trained staff can reach them without stepping deeper into danger. Annual servicing by a competent technician (starting from £80 with Landlord Certificate London), backed by monthly visual checks for pressure gauges and tamper seals, ensures every unit is ready if a small fire breaks out.

Frequently Asked Questions

How can building occupants actively participate in fire risk assessments?
Tenants and employees can support fire safety by reporting damaged fire doors, blocked corridors, or faulty emergency lights straight away, taking part in evacuation drills, and keeping communal hallways clear of bikes, prams, and rubbish bags.
What are the most common misconceptions about Fire Risk Assessments?
A frequent myth is that small premises or properties with fewer than five staff do not need a written assessment, or that a certificate lasts forever once completed. In reality, regular reviews are mandatory and all findings must be properly recorded.
What are the legal rules for Fire Risk Assessment documentation?
Under Section 156 of the Building Safety Act 2022 (amending the Regulatory Reform (Fire Safety) Order 2005), all Responsible Persons must record their Fire Risk Assessment and fire safety arrangements in full, regardless of the size of the business or number of employees.
How can technology improve Fire Risk Assessment record-keeping?
Digital compliance portals, QR-coded fire door and extinguisher asset tags, and automated renewal reminders help landlords track remedial actions with photographic proof and maintain a clear audit trail for insurers and council inspectors.
What role does insurance play in Fire Risk Assessments?
Most commercial and landlord building insurance policies require an up-to-date Fire Risk Assessment and documented maintenance of alarms, fire doors, and extinguishers as a condition of cover. Failing to keep records current can invalidate a claim after a fire.

Other Landlord Compliance Services

Book Your Fire Risk Assessment in London

Arrange an accredited inspection online or contact our team on 020 4518 8198 or info@landlordcertificatelondon.co.uk.

Book Online Now

Share this Article:

About the Author: Hassan Sharif

Hassan Sharif is a Business & Sales Developer at Landlord Certificate London, managing B2B relationships with estate agencies, letting agents and block managers across London and the M25. An MSc graduate in Advertising, Marketing and Media from the University of Essex, he is also a Domestic Energy Assessor, Fire Risk Assessor, and Retrofit Coordinator & Assessor, specialising in statutory property compliance and safety certification.

Leave A Comment