Timber Fire Doors: FD30 & FD60 Supply and Installation
Properly specified timber fire doors, fitted to the tolerances the doorset specification actually requires, not just a door that looks the part. We supply and install FD30 and FD60 doorsets for landlords, HMOs, flats and small commercial premises across London.
Why the timber matters as much as the rating
A fire door only works properly if the whole doorset works together , the leaf, the frame, the seals, the hinges, the ironmongery and the gaps around every edge.
We get called out fairly often to properties where someone’s fitted a fire-rated door onto an unsuitable frame, used incompatible components, or left the gaps around the leaf too wide. The door might look fine sitting there, but incorrect installation can compromise the fire and smoke performance the doorset was designed and tested to provide.
Timber fire doors are still a common choice for flats, HMOs and converted houses across London, mainly because they’re available in finishes that match the rest of the property and don’t look institutional.
The trade-off is that timber fire doors need more care in how they’re specified and fitted than a lot of people realise, which is really the whole point of using someone familiar with fire door installations rather than treating it like an ordinary internal door.
FD30 vs FD60: what the rating actually covers
The number after “FD” indicates the period of fire resistance the door or doorset is designed and tested to provide under the relevant fire test evidence. The required performance depends on the complete installation, including the door leaf, frame, seals, glazing where applicable, ironmongery and installation details, not simply the door leaf on its own.
| FD30 | FD60 | |
|---|---|---|
| Fire resistance | 30 minutes | 60 minutes |
| Typical leaf thickness | Often around 44mm, depending on the manufacturer and tested specification | Often thicker than FD30, commonly around 54mm, depending on the manufacturer and tested specification |
| Construction | Varies according to the manufacturer’s tested door design | Varies according to the manufacturer’s tested door design |
| Common use | Used where 30-minute fire resistance is specified, including many flat entrance, HMO and internal fire-door applications | Used where 60-minute fire resistance is specified, including certain higher-risk areas, protected routes, plant areas and other locations requiring increased protection |
| Frame & seals | Compatible frame, seals and ironmongery in accordance with the tested doorset specification | Compatible frame, seals and ironmongery in accordance with the tested doorset specification |
You’ll also see FD30S and FD60S written on specifications and door documentation. The “S” indicates smoke-control performance, normally achieved using suitable cold-smoke seals around the doorset in accordance with the tested specification.
Smoke control is particularly important on escape routes and flat entrance doors, and an FD30S or FD60S specification may be required depending on the building, location of the door and applicable fire safety requirements.
What actually goes into a compliant installation
A properly specified fire door installation can include:
Incorrect gaps, incompatible ironmongery, unsuitable frames, missing seals or alterations to a fire door can compromise the tested fire performance of the doorset. Installation should therefore follow the manufacturer’s instructions, certification or test evidence applicable to the particular door system rather than relying on a generic fire-door specification. A fire risk assessor, fire door inspector or Building Control professional checking the property afterwards may pick up on these details.
How we handle the job
The regulations behind this
Fire door requirements in England can arise under several areas of fire safety and building legislation. For new building work, alterations and certain replacement work, Building Regulations and Approved Document B provide relevant fire-safety guidance.
Fire resistance of doorsets may be demonstrated using appropriate test and classification evidence under applicable standards, including BS 476-22 and BS EN 1634-1, depending on the product and specification being used.
For premises within the scope of the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person must ensure that appropriate fire precautions are in place and maintained. A suitable and sufficient fire risk assessment is used to determine the fire precautions required for the premises.
The Fire Safety Act 2021 clarified that, in multi-occupied residential buildings, flat entrance doors between domestic premises and common parts fall within the scope of the Fire Safety Order.
The Fire Safety (England) Regulations 2022 introduced additional duties from January 2023. In residential buildings with a top storey more than 11 metres above ground level, Responsible Persons are required to use best endeavours to check flat entrance fire doors at least every 12 months and check fire doors in communal areas at least every three months.
None of this automatically tells you exactly which doors in your specific property need replacing or upgrading. That comes down to the property, its design, existing fire precautions, fire risk assessment and, where applicable, your council’s HMO licence conditions. If you’ve got either document, send it over and we’ll quote against what’s actually been specified rather than guessing.
Why book this through us rather than a joinery firm
Plenty of carpentry companies will hang a door for you. Fire door work needs more than making sure the door simply opens, closes and looks right. The door leaf, frame, seals, hinges, closer, ironmongery, glazing where applicable, gaps and method of installation all need to work together in accordance with the doorset specification.
If your doors are already fitted and you just need them checked, our fire door inspection and certificate service covers that separately.
Cost
Pricing depends on the number of doors, whether it’s FD30 or FD60, whether smoke control, glazing or specific ironmongery is required, and whether we’re working with a suitable existing opening or carrying out a full frame replacement. We’ll confirm a fixed price once we know the scope, so you know the agreed cost before the work is booked.
Frequently Asked Questions
Book your timber fire door installation
Whether it’s one flat entrance door or a full set of FD30 and FD60 doors across an HMO, tell us what you’re working with and we’ll quote against the actual requirement, not a generic specification.