Owning or managing a block of flats brings plenty of day-to-day responsibilities, and fire safety sits right at the top of that list. Whether you look after a purpose-built block or a house converted into self-contained apartments, knowing when a formal assessment is legally required protects both your residents and your legal standing.
Many freeholders and landlords assume an assessment only applies to large commercial buildings or high-rise towers. In reality, UK fire safety legislation casts a much wider net over multi-occupied residential buildings, and leaving a shared hallway or stairwell unassessed can expose the Responsible Person to enforcement notices and unlimited fines.


Across purpose-built blocks and Victorian conversions in London, the biggest blind spot we see is owners assuming a small building with no on-site staff needs no written paperwork. Even a two-flat conversion with a single shared entrance hallway requires a documented assessment, and councils routinely request it before issuing or renewing property licences.
Legal Rules Governing Fire Risk Assessments in Flats
Under the Regulatory Reform (Fire Safety) Order 2005, any building containing two or more domestic premises with shared common parts falls under statutory fire safety law. The Responsible Person (usually the freeholder, landlord, Right to Manage company, or managing agent) must carry out a suitable and sufficient Fire Risk Assessment covering all communal areas.
Two major updates have tightened those obligations across England. The Fire Safety Act 2021 confirmed that the structure, external walls (including cladding and balconies), and flat entrance doors opening onto common parts all sit inside the scope of your assessment. On top of that, Section 156 of the Building Safety Act 2022 removed the old five-employee threshold, meaning every Responsible Person must now record their full Fire Risk Assessment and fire safety arrangements in writing regardless of building size.
Four Key Situations That Require an Assessment
A Fire Risk Assessment is not a one-off tick-box exercise that stays valid forever. You need an initial assessment before a building is occupied, followed by structured reviews whenever risk factors shift.
Purpose-Built Blocks of Flats
Every purpose-built block with shared lobbies, corridors, bin stores, plant rooms, or stairwells needs a written assessment covering common parts and flat entrance doors.
Converted Houses and HMOs
Houses split into separate flats or Houses in Multiple Occupation (HMOs) carry higher compartmentation risks and almost always require an up-to-date assessment for local licensing.
After Building Works or Refurbishment
Loft conversions, internal layout changes, new cabling through fire-rated walls, or communal redecoration can breach fire stopping and trigger an immediate reassessment.
Changes in Occupancy or Management
A transfer of ownership, a switch in managing agent, a near-miss fire incident, or housing vulnerable residents with mobility needs all require a fresh review.
What an Assessor Checks Inside a Block of Flats
When a competent assessor inspects your property, they follow the five-step principles outlined in London Fire Brigade guidance: identifying ignition sources and fuel, checking who is at risk, evaluating existing fire precautions, recording findings in a clear action plan, and setting a sensible review schedule.

In residential blocks, special attention goes to escape routes, emergency lighting, fire alarm coverage, and passive fire protection. Where ducting or ventilation shafts pass between floors or flats, fire dampers play a vital role by closing off airways automatically during a fire to stop smoke and flames spreading. Keeping dampers inspected and emergency lighting tested ensures the building’s evacuation strategy holds up under real conditions.
Ongoing Duties Under the Fire Safety (England) Regulations 2022
For multi-occupied residential buildings in England, responsibilities go further than simply holding an assessment on file. Under the Fire Safety (England) Regulations 2022, Responsible Persons in all blocks with two or more flats must share clear fire safety instructions with residents, covering how to report a fire, the building’s evacuation or stay-put policy, and the importance of keeping fire doors shut.
If the building’s top storey sits above 11 metres in height, you must also carry out recorded quarterly checks on all communal fire doors and use best endeavours to inspect flat entrance doors every 12 months. Booking a dedicated fire door inspection helps confirm that intumescent strips, smoke seals, hinges, and self-closing devices all work as intended.
Assessment Scope by Residential Property Type
Different residential layouts present different fire risks. The table below outlines how assessment obligations apply across common UK property setups.
| Property Type | Is an Assessment Required? | Primary Focus Areas |
|---|---|---|
| Purpose-Built Block of Flats | Mandatory in writing for all shared common parts | Compartmentation, stay-put vs. evacuation strategy, flat entrance doors, external walls, risers, and stairwells |
| House Converted into Flats | Mandatory in writing where any shared hallway or landing exists | Upgrade of floors and doors to 30 or 60 minute fire resistance, interlinked detection, and clear escape routes |
| House in Multiple Occupation (HMO) | Mandatory in writing and required for council HMO licensing | Room-by-room fire doors, Grade A/D alarm coverage, kitchen fire risks, and protected escape routes |
| Guest Houses, B&Bs, and Holiday Lets | Mandatory in writing under the Fire Safety Order 2005 | Sleeping risk for unfamiliar guests, emergency lighting, signage, and clear evacuation instructions |
Landlord vs. Tenant Responsibilities for Fire Safety
Keeping a block of flats safe relies on cooperation between the building owner and the people living inside it. Each side holds distinct day-to-day duties.
Responsible Person (Landlord / Freeholder)
- Arrange and maintain a written Fire Risk Assessment by a competent person.
- Inspect and maintain communal fire doors, alarms, risers, and fire dampers.
- Keep shared corridors, lobbies, and stairwells clear of combustible items.
- Provide residents with clear fire safety instructions and door guidance.
Residents and Tenants
- Keep communal hallways and landings free of bikes, prams, and rubbish.
- Never wedge open fire doors or tamper with self-closing mechanisms.
- Test internal smoke alarms regularly and avoid overloading extension leads.
- Report damaged doors, faulty lighting, or fire hazards promptly to management.
Frequently Asked Questions
+Do I need a Fire Risk Assessment if my building only has two flats?
+How often should a Fire Risk Assessment for flats be reviewed?
+What are the penalties for failing to have a written Fire Risk Assessment?
+Are flat entrance doors included in the assessment?
+Do listed or historic flat conversions follow different rules?
Conclusion
A Fire Risk Assessment is legally required for almost every block of flats and converted residential building with shared common parts, and keeping that written record current is one of the smartest ways to protect residents and avoid enforcement action. By reviewing your building regularly, maintaining fire doors and dampers, and sharing clear safety instructions with tenants, you keep compliance straightforward year-round.
Need a Compliant Fire Risk Assessment for Your Flats?
Book an accredited assessor across London for a thorough, written Fire Risk Assessment tailored to your block or conversion.
Call us on 020 4518 8198 or email info@landlordcertificatelondon.co.uk
About the Author: Hassan Sharif
Related Posts
Get Social
Recent Posts
- Asbestos Management Surveys for London Rental Properties: CAR 2012 Landlord Guide
- Commercial Fire Risk Assessment London: Workplace Fire Compliance & Safety Certification
- Commercial Gas Safety Certificate CP42 London: Commercial Kitchen & Catering Compliance
- Landlord Gas Safety Certificate CP12 London: Annual Inspection & Legal Compliance Guide
- Commercial EICR London: Business Electrical Testing & Workplace Compliance Guide