What Is an Eicr Report

Share this Article:

Categories: EICRLast Updated: November 24, 2026By

Receiving an Electrical Installation Condition Report (EICR) can look intimidating if you have never read one before. Behind the summary page sits a structured technical record of your property’s fixed wiring, protective devices, test measurements, and any safety observations that need attention.

Qualified electrician reviewing an EICR report on site

Knowing how an EICR report is laid out, what each classification code means, and why inspection times vary helps landlords, homeowners, and commercial managers act quickly on urgent issues without getting bogged down in jargon.

What an EICR Report Contains

Every compliant EICR follows a standardised structure so councils, insurers, and future electricians can read the findings consistently. Rather than giving a vague pass or fail, the document breaks the installation down into clear sections:

Report SectionWhat It Shows You
Overall AssessmentStates clearly whether the fixed wiring is Satisfactory or Unsatisfactory for continued use.
Observations & CodesLists any defects or improvements found, graded as C1, C2, FI, or C3 with exact circuit locations.
Schedule of InspectionsRecords visual checks on earthing, consumer units, bathrooms, sockets, and cable condition.
Schedule of Test ResultsLogs measured continuity, insulation resistance, earth loop impedance, and RCD trip times per circuit.
Next Inspection DateConfirms the recommended interval (typically 5 years for rentals, or sooner if deterioration was noted).

Understanding C1, C2, C3, and FI Observation Codes

Any defects noted by your electrician are grouped into four classification codes. As outlined in GOV.UK electrical safety standards guidance, only C1, C2, and FI observations make a report Unsatisfactory and trigger the 28-day statutory deadline for remedial work:

C1: Danger Present

Immediate risk of injury, such as exposed live wires. The engineer must make the hazard safe before leaving site.

C2: Potentially Dangerous

Urgent remedial work is required within 28 days (or sooner if specified) to remove a latent shock or fire risk.

FI: Further Investigation

An unexpected reading or hidden fault needs immediate follow-up investigation to confirm safety.

C3: Improvement Recommended

Safe for continued use (Satisfactory), though upgrading older components is recommended to meet current standards.

EICR Inspection Duration and Testing Process

Electrical engineer testing circuits and distribution board for an EICR report

During the site visit, your engineer carries out visual inspections alongside Earth Continuity checks, Insulation Resistance tests, Earth Fault Loop Impedance measurements, and RCD trip-time tests against BS 7671 (the 18th Edition IET Wiring Regulations).

A compact flat with one consumer unit normally takes 1 to 2 hours, while larger family homes, HMOs, or multi-board commercial premises take longer depending on circuit counts, building age, and access to sockets and loft areas.

Hassan Sharif, Business Development Manager and Compliance Specialist

“Whenever a landlord receives an Unsatisfactory EICR, the most important page to check first is the Observations table, not just the cover sheet. Clear reports state the exact circuit and fault code so you know straight away whether you need a quick socket repair or a consumer unit upgrade within 28 days.”

Hassan Sharif, Business Development Manager & Compliance Specialist (View Profile)

Competency and Choosing a Reliable EICR Provider

Completed EICR electrical safety report and compliance documentation

As highlighted in Electrical Safety First landlord guidance, an EICR is only as reliable as the engineer carrying it out. Always choose a qualified inspector registered with a recognised competent person scheme (such as NICEIC or NAPIT) who holds City & Guilds 2391 inspection and testing credentials.

If you need a thorough, straightforward inspection in London with clear digital reporting, you can arrange your visit directly through our London EICR service.

Frequently Asked Questions

What is the difference between an EICR report and an EIC certificate?
An EICR (Electrical Installation Condition Report) assesses the safety of an existing installation. An EIC (Electrical Installation Certificate) is issued when brand-new circuits, a full rewire, or a new consumer unit are installed.
Do I get a separate pass certificate after fixing C1 or C2 faults?
After remedial repairs are completed, the electrician issues written confirmation (such as an Electrical Installation Certificate or Minor Works Certificate) confirming the faults are resolved, which you keep alongside your original EICR and send to the tenant and council within 28 days.
Can an EICR report have limitations listed on it?
Yes. If certain areas such as a locked cupboard, boarded loft, or concealed junction box cannot be accessed safely without causing damage, the engineer records agreed limitations on the report.
How quickly do I receive my EICR report after the inspection?
Digital EICR reports are normally completed and emailed within 24 to 48 hours of the site visit, ready to share with tenants, letting agents, or insurers.

Other Landlord Compliance Services

Need an EICR Report in London?

Book online in minutes or speak with our team on 020 4518 8198 or info@landlordcertificatelondon.co.uk.

Book Online Now

Share this Article:

About the Author: Hassan Sharif

Hassan Sharif is a Business & Sales Developer at Landlord Certificate London, managing B2B relationships with estate agencies, letting agents and block managers across London and the M25. An MSc graduate in Advertising, Marketing and Media from the University of Essex, he is also a Domestic Energy Assessor, Fire Risk Assessor, and Retrofit Coordinator & Assessor, specialising in statutory property compliance and safety certification.

Leave A Comment