An Electrical Installation Condition Report (EICR) is a formal safety inspection of the fixed electrical wiring, consumer unit, sockets, and lighting circuits inside a residential or commercial property. Carried out by a qualified electrician, the test pinpoints hidden wear, overloaded circuits, or missing protection before they cause electric shocks or electrical fires.
For landlords, business managers, and homebuyers across London, knowing what actually happens during an EICR electrical test removes the guesswork when booking an inspection or reviewing a report.
EICR Meaning and Purpose
Following a structured inspection and test, an EICR records whether a property’s fixed electrical installation is safe for continued use (Satisfactory) or requires urgent remedial repairs (Unsatisfactory). Under GOV.UK electrical safety standards guidance, landlords in England must obtain an EICR at least every five years, while insurers and commercial landlords rely on the same report to verify ongoing building safety.
You can view full residential options and transparent bedroom tiers on our London EICR service page before booking an appointment.
The EICR Test Procedure Explained

A thorough EICR combines a careful visual examination with dead and live electrical testing using calibrated multifunction instruments. Each stage checks a different layer of protection against BS 7671 (the 18th Edition IET Wiring Regulations):
Visual Inspection Checks
- Cracked sockets, loose light switches, or scorched faceplates
- Missing circuit labelling or damaged consumer unit enclosures
- Adequate IP ratings in bathrooms and damp zones
- Signs of DIY alterations or unsafe cable routing
Dead & Live Electrical Tests
- Continuity of protective conductors and ring final circuits
- Insulation resistance testing to catch degraded cable sheathing
- Earth fault loop impedance (Zs and Ze) verification
- RCD trip-time testing to confirm fast shock disconnection
Six-Point EICR Testing Checklist
Qualified electricians follow a methodical sequence so every part of the fixed installation is accounted for cleanly:
Verification of Earthing and Bonding: Confirms main earthing conductors and protective bonding to gas and water pipes meet current safety sizes.
Consumer Unit Examination: Checks the condition, RCD protection, MCB ratings, and circuit chart inside the fuse box.
Individual Circuit Testing: Tests lighting, socket rings, cooker, and shower circuits for continuity, polarity, and insulation resistance.
Accessory & Enclosure Checks: Inspects accessible sockets, fused spurs, and junction boxes for overheating or mechanical damage.
RCD & Live Loop Measurements: Verifies protective devices disconnect within safe millisecond limits under simulated fault conditions.
Classification Coding & Next Test Date: Assigns C1, C2, C3, or FI codes where needed and sets the recommended interval until the next inspection.

“Clients often ask why the power has to be switched off during an EICR. Dead testing for insulation resistance and ring continuity is only accurate when circuits are safely isolated, and it usually only lasts around 30 to 45 minutes per board before everything is turned back on.”
What a 5-Year Periodic Inspection Covers

A five-year periodic inspection evaluates how well the wiring, switchgear, and protective devices have held up since installation or the last report. For commercial properties, this supports legal duties under the HSE Electricity at Work Regulations 1989 (HSR25), checking RCD protection for outdoor-capable sockets, warning labels on distribution boards, and signs of thermal stress or corrosion.
Does an EICR Test Every Socket?

In most properties, an EICR does not require unscrewing every single socket faceplate off the wall. Instead, the inspector tests every circuit at the consumer unit and carries out representative sampling of sockets, switches, and light fittings, paying closer attention to higher-wear zones such as kitchens, bathrooms, and older extensions.
If sampling uncovers loose terminations, missing earth sleeves, or unexpectedly high readings on a circuit, the engineer expands the inspection across more outlets on that circuit until the cause is clear.
Frequently Asked Questions
+ Can tenants request to see an EICR for their rental property?
+ How can an EICR affect home or landlord insurance?
+ What qualifications must an electrician hold to carry out an EICR?
+ Is an EICR mandatory for commercial properties in the UK?
+ What happens if I ignore Unsatisfactory EICR recommendations?
Other Landlord Compliance Services
Residential EICR
Five-year electrical installation safety reports for London flats and houses.
Commercial EICR
Circuit-tested electrical safety reports for shops, offices, and commercial units.
Emergency Lighting
BS 5266 emergency lighting testing and certification from £55.
Electrical Diagnostic
Targeted fault-finding for tripping breakers, dead sockets, and wiring issues.
PAT Testing
Portable appliance safety testing for furnished rentals and commercial equipment.
Fuse Box Installation
Part P certified 18th Edition consumer unit upgrades across Greater London.
Book Your EICR Electrical Test in London
Schedule your inspection online or speak with our team on 020 4518 8198 or info@landlordcertificatelondon.co.uk.
About the Author: Hassan Sharif
Related Posts
Get Social
Recent Posts
- Asbestos Management Surveys for London Rental Properties: CAR 2012 Landlord Guide
- Commercial Fire Risk Assessment London: Workplace Fire Compliance & Safety Certification
- Commercial Gas Safety Certificate CP42 London: Commercial Kitchen & Catering Compliance
- Landlord Gas Safety Certificate CP12 London: Annual Inspection & Legal Compliance Guide
- Commercial EICR London: Business Electrical Testing & Workplace Compliance Guide